Sale!

Metrel MD 9070 Digital Multimeter

Inquire for pricing

The MD 9070 is a high accuracy insulation and continuity multimeter which may be used in a CAT IV / 600 V environment. It’s dual digital display provides all needed data to the operator while it’s size ensures that it can be operated single handedly. The instrument is equipped with a built-in VFD feature that makes the instrument capable of measuring true RMS values in accordance with frequency, performing PI/DAR measurements and diode test. The MD 9070 has a wide range of extra features, including data hold, memory, min / max, differential, auto power off, auto-ranging, frequency filter, lock feature, reset, relative function and more.

Please use the request form to start a calibration services quote. You may also request equipment sales or repair services.

Service & PurchasePrice
Equipment repair to manufacturers specifications.Inquire for pricing
Calibration with 17025 accreditation.Inquire for pricing
Standard calibration to manufacturers specifications.Inquire for pricing
Calibration including pre and post calibration data.Inquire for pricing
Purchase equipment brand new.Inquire for pricing

SKU MetrelMD 9070 Category Manufacturer Model Number

Description

MD 9070 Insulation / Continuity Digital Multimeter

The MD 9070 is a high accuracy insulation and continuity multimeter which may be used in a CAT IV / 600 V environment. It’s dual digital display provides all needed data to the operator while it’s size ensures that it can be operated single handedly. The instrument is equipped with a built-in VFD feature that makes the instrument capable of measuring true RMS values in accordance with frequency, performing PI/DAR measurements and diode test. The MD 9070 has a wide range of extra features, including data hold, memory, min / max, differential, auto power off, auto-ranging, frequency filter, lock feature, reset, relative function and more.

Standards applied

Building LV Installation

  • IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – series
  • IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 1: General requirements
  • IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 2: Insulation resistance

Earthing and lightning protection

  • IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 4: Resistance of earth connection and equipotential bonding

Mobile Units Electrical Safety

  • eMOB Competences: Electrical LV Installations in Mobile Units Safety
  • IEC/EN/HD 60364-7-717 Low-voltage electrical installations: Requirements for special installations or locations – Supplies for Electrical Vehicles
  • UN ECE R 100 Uniform provisions concerning the approval of vehicles with regard to specific requirements for the electric power train [2015/505]

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
  • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements

Instrument safety towards user

  • IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
  • IEC/EN 61000 Electromagnetic compatibility (EMC) series
  • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
  • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
  • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
  • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
  • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
  • IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
  • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
  • IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
  • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
  • Directive EMC 2004/108/EC on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
  • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
  • IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

Properties

Measuring functions

  • TRMS measurement;
  • Insulation resistance measurement;
  • Earth continuity measurement;
  • Resistance measurement;
  • Diode test;
  • Mains supply frequency measurement;
  • Frequency of digital signals measurement.

Key features

  • TRMS: accurate readings on sinusoidal and non-sinusoidal signals.
  • VFD: feature makes the instrument capable of measuring the true values in accordance with frequency.
  • Auto-ranging: user can switch between auto and manual ranging.
  • Relative zero mode: relative function for comparing the difference between signals or removing background noise.
  • MAX/MIN: recording of maximum, minimum and average values.
  • Data Hold: data hold feature freezes the display for later view.
  • PI/DAR: feature.
  • Safety: CAT IV / 600 V and CAT III / 1000 V overvoltage protection.
  • Backlight: working in dark conditions.

Technical data

  • Dimensions (w x h x l): 103 x 64,5 x 208 mm
  • Mass (without accessories): 635 g

Applications

Preventative maintenance

  • Earth continuity and insulation testing
  • Voltage measurements
  • Frequency measurements

Troubleshooting

  • Installation troubleshooting
  • Field service
Main Features
Voltage DC
DC 1000 V
Voltage AC
Frequency
Voltage TRMS
AC 1000 V
Other DMM measurements
Acoustic continuity
Resistance
Capacitance
Diode test
Temperature measurement
Earth Bond / Continuity
Max Test Current 90 mA 2-wire
Max Test Current 200 mA 2-wire
Insulation Resistance
Test Voltage 50 V
Test Voltage 100 V
Test Voltage 250 V
Test Voltage 500 V
Test Voltage 1000 V
Max resistance range 25 TOhm
Calculation of PI
Calculation of DAR
Additional Features
Hand-Held
Hand-Held
Measurement detection
Incorrect lead connection alert
Low Pass filter
Variable frequency drive
Data hold
Data hold
MAX/MIN/AVG recording
Self-Calibration
Relative zero
Display
LCD
Dual digital
Back Light
Power Supply
Battery Powered
Buzzer
Buzzer
Graphical user interface
Bar Graph
Other applications
Preventative maintenance
Earth continuity and insulation testing
Voltage measurements
Frequency measurements
Troubleshooting
Installation troubleshooting
Field service
Standards Applied
Building LV Installation
IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – series
IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 1: General requirements
IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 2: Insulation resistance
Earthing and lightning protection
IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC – Equipment for testing, measuring or monitoring of protective measures – Part 4: Resistance of earth connection and equipotential bonding
Mobile Units Electrical Safety
eMOB Competences: Electrical LV Installations in Mobile Units Safety
IEC/EN/HD 60364-7-717 Low-voltage electrical installations: Requirements for special installations or locations – Supplies for Electrical Vehicles
UN ECE R 100 Uniform provisions concerning the approval of vehicles with regard to specific requirements for the electric power train [2015/505]
Instrument safety towards user
IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
IEC/EN 61000 Electromagnetic compatibility (EMC) series
IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
Directive EMC 2004/108/EC on electromagnetic compatibility
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety
IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements

Laboratory Calibration

Micro Precision operates 36 laboratories globally providing reliable localized support

  • Certified metrologists staffing laboratories in North America, Central America, South America, Europe, Asia, and the Middle East
  • Comprehensive scopes of accreditation to meet a broad range of customer needs
  • Expedited calibration services available
  • Pickup and delivery services available
  • Environmentally controlled facilities to ensure high quality and accurate calibrations and measurements.

Calibration equipment and workspace
Calibration Service For This Equipment

Laboratory Calibration

Micro Precision operates 36 laboratories globally providing reliable localized support

  • Certified metrologists staffing laboratories in North America, Central America, South America, Europe, Asia, and the Middle East
  • Comprehensive scopes of accreditation to meet a broad range of customer needs
  • Expedited calibration services available
  • Pickup and delivery services available
  • Environmentally controlled facilities to ensure high quality and accurate calibrations and measurements.

Calibration Service For This Equipment
Calibration equipment and workspace

Quality Certified Test Equipment Repair Services

When a piece of equipment fails you have the option to repair or replace that item. Oftentimes repair is an economical and efficient solution. Micro Precision’s repair offering provides advantages to our customers:

  • Cost effective; often less than OEM
  • Efficient; often much better turn-time than the OEM
  • Flexibility; willingness to work with customers to meet their needs
  • Warranted repairs
  • Ability to service many obsolete instruments

Motherboard being repaired with soldering iron
Repair Service For This Equipment
Motherboard being repaired with soldering iron

Quality Certified Test Equipment Repair Services

When a piece of equipment fails you have the option to repair or replace that item. Oftentimes repair is an economical and efficient solution. Micro Precision’s repair offering provides advantages to our customers:

  • Cost effective; often less than OEM
  • Efficient; often much better turn-time than the OEM
  • Flexibility; willingness to work with customers to meet their needs
  • Warranted repairs
  • Ability to service many obsolete instruments

Repair Service For This Equipment

Cost Effective Test Equipment Options

From the leasing of specialized electronic equipment for a specific task, to the purchase of physical and dimensional tools, we offer leasing services as well as used test equipment sales. We also locate hard-to-find electronics, and provide flexible options to meet ever-changing equipment needs.

Electronic instruments stacked on top of one another
Rent or Purchase This Equipment

Cost Effective Test Equipment Options

From the leasing of specialized electronic equipment for a specific task, to the purchase of physical and dimensional tools, we offer leasing services as well as used test equipment sales. We also locate hard-to-find electronics, and provide flexible options to meet ever-changing equipment needs.

Rent or Purchase This Equipment
Electronic instruments stacked on top of one another

Our Capabilities

Micro Precision can perform instrument calibration services on equipment from variety of applications for specific industries and lines of business. If you have a calibration need that is not listed in this area, please contact us.

Electrical

Micro Precision accredited electrical calibration lab services with multimeter, multifunction calibrator, oscilloscope, and power supply capabilities.

About Electrical

Optical

Micro Precision accredited optical, light, and fiber optic calibration lab services.

About Optical

Thermodynamics & Chemical

Micro Precision accredited thermodynamic & chemical calibration lab services with temperature, humidity, life science, and pharma capabilities.

About Thermodynamics

RF - Microwave

Micro Precision accredited RF & microwave calibration lab services.

About RF & Microwave

Mechanical & Dimensional

Micro Precision accredited mechanical and dimensional calibration lab services with pressure, torque, force, flow, velocity, and aircraft jack load capabilities.

About Mechanical

Laboratory Standards

Calibration laboratory standards are critical for your organization’s most accurate measurements.

About Laboratory Standards

Semiconductor Calibration

Micro Precision utilizes state-of-the-art technology to analyze semiconductor wafer thickness and step height.

About Semiconductor