Sale!

Metrel MD 9060 Digital Multimeter

Inquire for pricing

The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement,  conductance measurement and fast one-handed operation.  MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice.

Please use the request form to start a calibration services quote. You may also request equipment sales or repair services.

Service & PurchasePrice
Equipment repair to manufacturers specifications.Inquire for pricing
Calibration with 17025 accreditation.Inquire for pricing
Standard calibration to manufacturers specifications.Inquire for pricing
Calibration including pre and post calibration data.Inquire for pricing
Purchase equipment brand new.Inquire for pricing

SKU MetrelMD 9060 Category Manufacturer Model Number

Description

MD 9060 TRMS, 500.000 counts LCD, 100k Hz Voltage Bandwidth Heavy Duty Industrial Multimeter

The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement,  conductance measurement and fast one-handed operation.  MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice. .

Standards applied

Instrument safety towards user

  • IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
  • IEC/EN 61000 Electromagnetic compatibility (EMC) series
  • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
  • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
  • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
  • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
  • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
  • IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
  • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
  • IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
  • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
  • Directive EMC 2004/108/EC on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
  • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
  • IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
  • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements

Properties

Measuring functions

  • TRMS AC, DC voltage measurement;
  • TRMS AC, DC current measurement;
  • Capacitance measurement;
  • Resistance measurement;
  • Diode test;
  • Mains supply frequency measurement;
  • Frequency of digital signals measurement;
  • Continuity test (acoustic signalling);
  • Conductance measurement;
  • Temperature measurement.

Key features

  • TRMS: accurate readings on sinusoidal and non-sinusoidal signals.
  • VFD: feature makes the instrument capable of measuring the true values in accordance with frequency.
  • Auto-ranging: user can switch between auto and manual ranging.
  • Temperature measurement: measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
  • Lead alert: incorrect lead connection alert.
  • Relative zero mode: relative function for comparing the difference between signals or removing background noise.
  • MAX/MIN/AVG: recording of maximum, minimum and average values.
  • Data Hold: data hold feature freezes the display for later view.
  • Peak Hold: Crest (instantaneous peak) capture mode.
  • PC Link: test results can be downloaded to the computer via the optional PC software.
  • Safety: CAT IV / 1000 V overvoltage protection.
  • Backlight: large bright 4 digits 500.000 counts dual LCD display with backlight for working in dark conditions.

Technical data

  • Dimensions (w x h x l): 103 x 64,5 x 208 mm
  • Mass (without accessories): 635 g

Applications

Preventative maintenance

  • Voltage measurements
  • Current measurements
  • Frequency measurements

Troubleshooting

  • Field service
  • Electronics
  • HVAC

General purpose

  • Industrial testing
Main Features
Voltage DC
DC 1000 V
Voltage AC
Frequency
Voltage TRMS
AC 1000 V
Current DC
DC 10 A
Current AC
Current TRMS
AC 10 A
Other DMM measurements
Acoustic continuity
Resistance
Capacitance
Conductance
Diode test
Temperature measurement
Logic frequency
Automotive DMM measurements
% – Duty Cycle Function
Additional Features
Hand-Held
Hand-Held
Measurement detection
Incorrect lead connection alert
Low Pass filter
Variable frequency drive
100 kHz bandwidth
Data hold
Data hold
MAX hold
MAX/MIN/AVG recording
Self-Calibration
Relative zero
Display
LCD
Dual digital
Back Light
Power Supply
Battery Powered
Buzzer
Buzzer
Graphical user interface
Bar Graph
High precision resolution
High precision resolution
Optical Communication Port
Optical Communication Port
Special Accessories
Type K thermocouple probe for DMM
Type K thermocouple probe for DMM
PC Software Package
PC Software Package
PC Interface Set
Other applications
Preventative maintenance
Voltage measurements
Current measurements
Frequency measurements
Troubleshooting
Field service
Electronics
HVAC
General purpose
Industrial testing
Standards Applied
Instrument safety towards user
IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
IEC/EN 61000 Electromagnetic compatibility (EMC) series
IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
Directive EMC 2004/108/EC on electromagnetic compatibility
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety
IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements
Product ManualDownload

Laboratory Calibration

Micro Precision operates 36 laboratories globally providing reliable localized support

  • Certified metrologists staffing laboratories in North America, Central America, South America, Europe, Asia, and the Middle East
  • Comprehensive scopes of accreditation to meet a broad range of customer needs
  • Expedited calibration services available
  • Pickup and delivery services available
  • Environmentally controlled facilities to ensure high quality and accurate calibrations and measurements.

Calibration equipment and workspace
Calibration Service For This Equipment

Laboratory Calibration

Micro Precision operates 36 laboratories globally providing reliable localized support

  • Certified metrologists staffing laboratories in North America, Central America, South America, Europe, Asia, and the Middle East
  • Comprehensive scopes of accreditation to meet a broad range of customer needs
  • Expedited calibration services available
  • Pickup and delivery services available
  • Environmentally controlled facilities to ensure high quality and accurate calibrations and measurements.

Calibration Service For This Equipment
Calibration equipment and workspace

Quality Certified Test Equipment Repair Services

When a piece of equipment fails you have the option to repair or replace that item. Oftentimes repair is an economical and efficient solution. Micro Precision’s repair offering provides advantages to our customers:

  • Cost effective; often less than OEM
  • Efficient; often much better turn-time than the OEM
  • Flexibility; willingness to work with customers to meet their needs
  • Warranted repairs
  • Ability to service many obsolete instruments

Motherboard being repaired with soldering iron
Repair Service For This Equipment
Motherboard being repaired with soldering iron

Quality Certified Test Equipment Repair Services

When a piece of equipment fails you have the option to repair or replace that item. Oftentimes repair is an economical and efficient solution. Micro Precision’s repair offering provides advantages to our customers:

  • Cost effective; often less than OEM
  • Efficient; often much better turn-time than the OEM
  • Flexibility; willingness to work with customers to meet their needs
  • Warranted repairs
  • Ability to service many obsolete instruments

Repair Service For This Equipment

Cost Effective Test Equipment Options

From the leasing of specialized electronic equipment for a specific task, to the purchase of physical and dimensional tools, we offer leasing services as well as used test equipment sales. We also locate hard-to-find electronics, and provide flexible options to meet ever-changing equipment needs.

Electronic instruments stacked on top of one another
Rent or Purchase This Equipment

Cost Effective Test Equipment Options

From the leasing of specialized electronic equipment for a specific task, to the purchase of physical and dimensional tools, we offer leasing services as well as used test equipment sales. We also locate hard-to-find electronics, and provide flexible options to meet ever-changing equipment needs.

Rent or Purchase This Equipment
Electronic instruments stacked on top of one another

Our Capabilities

Micro Precision can perform instrument calibration services on equipment from variety of applications for specific industries and lines of business. If you have a calibration need that is not listed in this area, please contact us.

Electrical

Micro Precision accredited electrical calibration lab services with multimeter, multifunction calibrator, oscilloscope, and power supply capabilities.

About Electrical

Optical

Micro Precision accredited optical, light, and fiber optic calibration lab services.

About Optical

Thermodynamics & Chemical

Micro Precision accredited thermodynamic & chemical calibration lab services with temperature, humidity, life science, and pharma capabilities.

About Thermodynamics

RF - Microwave

Micro Precision accredited RF & microwave calibration lab services.

About RF & Microwave

Mechanical & Dimensional

Micro Precision accredited mechanical and dimensional calibration lab services with pressure, torque, force, flow, velocity, and aircraft jack load capabilities.

About Mechanical

Laboratory Standards

Calibration laboratory standards are critical for your organization’s most accurate measurements.

About Laboratory Standards

Semiconductor Calibration

Micro Precision utilizes state-of-the-art technology to analyze semiconductor wafer thickness and step height.

About Semiconductor