Metrel MD 9050 Digital Multimeter
The MD 9050 ranks among the best multimeters on the market. High resolution and accuracy, 2-line LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement, non-contact voltage detection, conductance measurement, auto check function and fast one-handed operation are highlights of the multimeter. The MD 9050 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice.
Please use the request form to start a calibration services quote. You may also request equipment sales or repair services.
Service & Purchase | Price |
---|---|
Equipment repair to manufacturers specifications. | Inquire for pricing |
Calibration with 17025 accreditation. | Inquire for pricing |
Standard calibration to manufacturers specifications. | Inquire for pricing |
Calibration including pre and post calibration data. | Inquire for pricing |
Purchase equipment brand new. | Inquire for pricing |
Description
MD 9050 TRMS Heavy Duty Industrial Digital Multimeter
The MD 9050 ranks among the best multimeters on the market. High resolution and accuracy, 2-line LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement, non-contact voltage detection, conductance measurement, auto check function and fast one-handed operation are highlights of the multimeter. The MD 9050 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice.
Standards applied
Instrument safety towards user
- IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
- IEC/EN 61000 Electromagnetic compatibility (EMC) series
- IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
- IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
- IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
- IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
- IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
- IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
- IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
- IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
- IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
- The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
- Directive EMC 2004/108/EC on electromagnetic compatibility
- IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
- IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
- IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
- IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
- IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety
- IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
- IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements
Properties
Measuring functions
- TRMS AC, DC voltage measurement;
- TRMS AC, DC current measurement;
- Capacitance measurement;
- Resistance measurement;
- Diode test;
- Mains supply frequency measurement;
- Frequency of digital signals measurement;
- Continuity test (acoustic signalling);
- Conductance measurement;
- Electric field detection;
- Temperature measurement.
Key features
- TRMS: accurate readings on sinusoidal and non-sinusoidal signals.
- Autocheck function: automatic detection of AC voltage, DC voltage or resistance.
- Auto-ranging: user can switch between auto and manual ranging.
- Temperature measurement: measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
- EF detection: non-contact and probe-contact electric field detection.
- Lead alert: incorrect lead connection alert.
- Relative zero mode: relative function for comparing the difference between signals or removing background noise.
- MAX/MIN/AVG: recording of maximum, minimum and average values.
- Data Hold: data hold feature freezes the display for later view.
- Peak Hold: Crest (instantaneous peak) cupture mode.
- PC Link: test results can be downloaded to the computer via the optional PC software.
- Safety: CAT IV / 1000 V overvoltage protection.
- Backlight: large bright 4 digits 9999 counts dual LCD display with backlight for working in dark conditions.
Technical data
- Dimensions (w x h x l): 103 x 64,5 x 208 mm
- Mass (without accessories): 635 g
Applications
Secondary power sources in healthcare
- Generator safety
Preventative maintenance
- Voltage measurements
- Current measurements
- Frequency measurements
Troubleshooting
- Appliances troubleshooting
- Field service
- Electronics
- HVAC
General purpose
- Industrial testing
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
उत्पादों को खोजना
प्रयोगशाला अंशांकन
माइक्रो प्रिसिजन विश्व स्तर पर 36 प्रयोगशालाओं का संचालन करती है जो विश्वसनीय स्थानीय सहायता प्रदान करती हैं
<उल>
प्रयोगशाला अंशांकन
माइक्रो प्रिसिजन विश्व स्तर पर 36 प्रयोगशालाओं का संचालन करती है जो विश्वसनीय स्थानीय सहायता प्रदान करती हैं
<उल>
गुणवत्ता प्रमाणित परीक्षण उपकरण मरम्मत सेवाएं
जब उपकरण का एक टुकड़ा विफल हो जाता है तो आपके पास उस वस्तु की मरम्मत या बदलने का विकल्प होता है। अक्सर मरम्मत एक किफायती और कुशल समाधान है। माइक्रो प्रिसिजन की मरम्मत की पेशकश हमारे ग्राहकों को लाभ प्रदान करती है:
<उल>
गुणवत्ता प्रमाणित परीक्षण उपकरण मरम्मत सेवाएं
जब उपकरण का एक टुकड़ा विफल हो जाता है तो आपके पास उस वस्तु की मरम्मत या बदलने का विकल्प होता है। अक्सर मरम्मत एक किफायती और कुशल समाधान है। माइक्रो प्रिसिजन की मरम्मत की पेशकश हमारे ग्राहकों को लाभ प्रदान करती है:
<उल>
लागत प्रभावी परीक्षण उपकरण विकल्प
किसी विशिष्ट कार्य के लिए विशेष इलेक्ट्रॉनिक उपकरणों को पट्टे पर देने से लेकर भौतिक और आयामी उपकरणों की खरीद तक, हम लीजिंग सेवाओं के साथ-साथ उपयोग किए गए परीक्षण उपकरण की बिक्री की पेशकश करते हैं। हम हार्ड-टू-फाइंड इलेक्ट्रॉनिक्स का भी पता लगाते हैं, और हमेशा बदलती उपकरणों की जरूरतों को पूरा करने के लिए लचीले विकल्प प्रदान करते हैं।
लागत प्रभावी परीक्षण उपकरण विकल्प
किसी विशिष्ट कार्य के लिए विशेष इलेक्ट्रॉनिक उपकरणों को पट्टे पर देने से लेकर भौतिक और आयामी उपकरणों की खरीद तक, हम लीजिंग सेवाओं के साथ-साथ उपयोग किए गए परीक्षण उपकरण की बिक्री की पेशकश करते हैं। हम हार्ड-टू-फाइंड इलेक्ट्रॉनिक्स का भी पता लगाते हैं, और हमेशा बदलती उपकरणों की जरूरतों को पूरा करने के लिए लचीले विकल्प प्रदान करते हैं।
हमारी क्षमताएं
माइक्रो प्रेसिजन विशिष्ट उद्योगों और व्यवसाय की लाइनों के लिए विभिन्न प्रकार के अनुप्रयोगों से उपकरणों पर उपकरण अंशांकन सेवाएं कर सकता है। यदि आपके पास अंशांकन की आवश्यकता है जो इस क्षेत्र में सूचीबद्ध नहीं है, तो कृपया हमसे संपर्क करें।
विद्युतीय
मल्टीमीटर, मल्टीफ़ंक्शन कैलिब्रेटर, ऑसिलोस्कोप, और बिजली आपूर्ति क्षमताओं के साथ माइक्रो प्रेसिजन मान्यता प्राप्त विद्युत अंशांकन प्रयोगशाला सेवाएं।
ऑप्टिकल
माइक्रो प्रेसिजन मान्यता प्राप्त ऑप्टिकल, लाइट और फाइबर ऑप्टिक कैलिब्रेशन लैब सेवाएं।
रासायनिक
तापमान, आर्द्रता, जीवन विज्ञान और फार्मा क्षमताओं के साथ माइक्रो प्रेसिजन मान्यता प्राप्त थर्मोडायनामिक और रासायनिक अंशांकन प्रयोगशाला सेवाएं।
आरएफ - माइक्रोवेव
माइक्रो प्रेसिजन मान्यता प्राप्त आरएफ और माइक्रोवेव अंशांकन प्रयोगशाला सेवाएं।
यांत्रिक और आयामी
दबाव, टोक़, बल, प्रवाह, वेग और विमान जैक लोड क्षमताओं के साथ सूक्ष्म परिशुद्धता मान्यता प्राप्त यांत्रिक और आयामी अंशांकन प्रयोगशाला सेवाएं।
सेमीकंडक्टर
ANAB को ISO/IEC 17025-2017 से मान्यता प्राप्त सेमीकंडक्टर वेफर मोटाई और सटीक स्टेप हाइट कैलिब्रेशन से मान्यता प्राप्त है।
अंशांकन की जरूरत है। सरलीकृत।
पूर्ण स्टैक परीक्षण उपकरण और उपकरण अंशांकन सेवाएं।
वैश्विक समाधान
तकनीकी और गुणवत्ता मूल्य वर्धित सेवाएं, ओईएम समर्थन और परिसंपत्ति प्रबंधन समाधान प्रदान करना।