ลดราคา!

Metrel MD 9060 Digital Multimeter

Inquire for pricing

The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement,  conductance measurement and fast one-handed operation.  MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice.

Please use the request form to start a calibration services quote. You may also request equipment sales or repair services.

Service & PurchasePrice
Equipment repai …Inquire for pricing
Calibration wit …Inquire for pricing
Standard calibr …Inquire for pricing
Calibration inc …Inquire for pricing
Purchase equipm …Inquire for pricing

รหัสสินค้า MetrelMD 9060 หมวดหมู่ Manufacturer Model Number

รายละเอียดเพิ่มเติม

MD 9060 TRMS, 500.000 counts LCD, 100k Hz Voltage Bandwidth Heavy Duty Industrial Multimeter

The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement,  conductance measurement and fast one-handed operation.  MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice. .

Standards applied

Instrument safety towards user

  • IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
  • IEC/EN 61000 Electromagnetic compatibility (EMC) series
  • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
  • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
  • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
  • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
  • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
  • IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
  • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
  • IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
  • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
  • Directive EMC 2004/108/EC on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
  • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
  • IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
  • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements

Properties

Measuring functions

  • TRMS AC, DC voltage measurement;
  • TRMS AC, DC current measurement;
  • Capacitance measurement;
  • Resistance measurement;
  • Diode test;
  • Mains supply frequency measurement;
  • Frequency of digital signals measurement;
  • Continuity test (acoustic signalling);
  • Conductance measurement;
  • Temperature measurement.

Key features

  • TRMS: accurate readings on sinusoidal and non-sinusoidal signals.
  • VFD: feature makes the instrument capable of measuring the true values in accordance with frequency.
  • Auto-ranging: user can switch between auto and manual ranging.
  • Temperature measurement: measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
  • Lead alert: incorrect lead connection alert.
  • Relative zero mode: relative function for comparing the difference between signals or removing background noise.
  • MAX/MIN/AVG: recording of maximum, minimum and average values.
  • Data Hold: data hold feature freezes the display for later view.
  • Peak Hold: Crest (instantaneous peak) capture mode.
  • PC Link: test results can be downloaded to the computer via the optional PC software.
  • Safety: CAT IV / 1000 V overvoltage protection.
  • Backlight: large bright 4 digits 500.000 counts dual LCD display with backlight for working in dark conditions.

Technical data

  • Dimensions (w x h x l): 103 x 64,5 x 208 mm
  • Mass (without accessories): 635 g

Applications

Preventative maintenance

  • Voltage measurements
  • Current measurements
  • Frequency measurements

Troubleshooting

  • Field service
  • Electronics
  • HVAC

General purpose

  • Industrial testing
Main Features
Voltage DC
DC 1000 V
Voltage AC
Frequency
Voltage TRMS
AC 1000 V
Current DC
DC 10 A
Current AC
Current TRMS
AC 10 A
Other DMM measurements
Acoustic continuity
Resistance
Capacitance
Conductance
Diode test
Temperature measurement
Logic frequency
Automotive DMM measurements
% – Duty Cycle Function
Additional Features
Hand-Held
Hand-Held
Measurement detection
Incorrect lead connection alert
Low Pass filter
Variable frequency drive
100 kHz bandwidth
Data hold
Data hold
MAX hold
MAX/MIN/AVG recording
Self-Calibration
Relative zero
Display
LCD
Dual digital
Back Light
Power Supply
Battery Powered
Buzzer
Buzzer
Graphical user interface
Bar Graph
High precision resolution
High precision resolution
Optical Communication Port
Optical Communication Port
Special Accessories
Type K thermocouple probe for DMM
Type K thermocouple probe for DMM
PC Software Package
PC Software Package
PC Interface Set
Other applications
Preventative maintenance
Voltage measurements
Current measurements
Frequency measurements
Troubleshooting
Field service
Electronics
HVAC
General purpose
Industrial testing
Standards Applied
Instrument safety towards user
IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
IEC/EN 61000 Electromagnetic compatibility (EMC) series
IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
Directive EMC 2004/108/EC on electromagnetic compatibility
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety
IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements
Product ManualDownload

ค้นหาสินค้า


การสอบเทียบในห้องปฏิบัติการ

Micro Precision ดำเนินการห้องปฏิบัติการ 36 แห่งทั่วโลกโดยให้การสนับสนุนในพื้นที่ที่เชื่อถือได้

  • นักมาตรวิทยาที่ผ่านการรับรองซึ่งจัดพนักงานในห้องปฏิบัติการในอเมริกาเหนือ อเมริกากลาง อเมริกาใต้ ยุโรป เอเชีย และตะวันออกกลาง
  • ขอบเขตการรับรองที่ครอบคลุมเพื่อตอบสนองความต้องการของลูกค้าที่หลากหลาย
  • มีบริการสอบเทียบแบบเร่งด่วน
  • มีบริการรับ-ส่ง
  • สิ่งอำนวยความสะดวกที่ควบคุมสิ่งแวดล้อมเพื่อให้แน่ใจว่ามีการสอบเทียบและการวัดที่แม่นยำและมีคุณภาพสูง
Calibration equipment and workspace
บริการสอบเทียบสำหรับอุปกรณ์นี้

การสอบเทียบในห้องปฏิบัติการ

Micro Precision ดำเนินการห้องปฏิบัติการ 36 แห่งทั่วโลกโดยให้การสนับสนุนในพื้นที่ที่เชื่อถือได้

  • นักมาตรวิทยาที่ผ่านการรับรองซึ่งจัดพนักงานในห้องปฏิบัติการในอเมริกาเหนือ อเมริกากลาง อเมริกาใต้ ยุโรป เอเชีย และตะวันออกกลาง
  • ขอบเขตการรับรองที่ครอบคลุมเพื่อตอบสนองความต้องการของลูกค้าที่หลากหลาย
  • มีบริการสอบเทียบแบบเร่งด่วน
  • มีบริการรับ-ส่ง
  • สิ่งอำนวยความสะดวกที่ควบคุมสิ่งแวดล้อมเพื่อให้แน่ใจว่ามีการสอบเทียบและการวัดที่แม่นยำและมีคุณภาพสูง
บริการสอบเทียบสำหรับอุปกรณ์นี้
Calibration equipment and workspace

บริการซ่อมอุปกรณ์ทดสอบที่ผ่านการรับรองคุณภาพ

เมื่อชิ้นส่วนของอุปกรณ์ล้มเหลว คุณสามารถเลือกซ่อมแซมหรือเปลี่ยนรายการนั้นได้ การซ่อมแซมบ่อยครั้งเป็นวิธีแก้ปัญหาที่ประหยัดและมีประสิทธิภาพ ข้อเสนอการซ่อมของ Micro Precision มอบข้อได้เปรียบให้กับลูกค้าของเรา:

  • คุ้มค่า; มักจะน้อยกว่า OEM
  • มีประสิทธิภาพ; มักจะเปิดเวลาดีกว่า OEM
  • ความยืดหยุ่น; ความเต็มใจที่จะทำงานร่วมกับลูกค้าเพื่อตอบสนองความต้องการของพวกเขา
  • รับประกันการซ่อม
  • ความสามารถในการให้บริการเครื่องมือที่ล้าสมัยจำนวนมาก
Motherboard being repaired with soldering iron
บริการซ่อมอุปกรณ์นี้
Motherboard being repaired with soldering iron

บริการซ่อมอุปกรณ์ทดสอบที่ผ่านการรับรองคุณภาพ

เมื่อชิ้นส่วนของอุปกรณ์ล้มเหลว คุณสามารถเลือกซ่อมแซมหรือเปลี่ยนรายการนั้นได้ การซ่อมแซมบ่อยครั้งเป็นวิธีแก้ปัญหาที่ประหยัดและมีประสิทธิภาพ ข้อเสนอการซ่อมของ Micro Precision มอบข้อได้เปรียบให้กับลูกค้าของเรา:

  • คุ้มค่า; มักจะน้อยกว่า OEM
  • มีประสิทธิภาพ; มักจะเปิดเวลาดีกว่า OEM
  • ความยืดหยุ่น; ความเต็มใจที่จะทำงานร่วมกับลูกค้าเพื่อตอบสนองความต้องการของพวกเขา
  • รับประกันการซ่อม
  • ความสามารถในการให้บริการเครื่องมือที่ล้าสมัยจำนวนมาก
บริการซ่อมอุปกรณ์นี้

ตัวเลือกอุปกรณ์ทดสอบที่คุ้มค่า

ตั้งแต่การให้เช่าอุปกรณ์อิเล็กทรอนิกส์เฉพาะสำหรับงานเฉพาะ ไปจนถึงการซื้อเครื่องมือทางกายภาพและมิติ เราให้บริการเช่าซื้อตลอดจนการขายอุปกรณ์ทดสอบที่ใช้แล้ว เรายังระบุตำแหน่งอุปกรณ์อิเล็กทรอนิกส์ที่หายาก และมีตัวเลือกที่ยืดหยุ่นเพื่อตอบสนองความต้องการอุปกรณ์ที่เปลี่ยนแปลงตลอดเวลา

Electronic instruments stacked on top of one another
เช่าหรือซื้ออุปกรณ์นี้

ตัวเลือกอุปกรณ์ทดสอบที่คุ้มค่า

ตั้งแต่การให้เช่าอุปกรณ์อิเล็กทรอนิกส์เฉพาะสำหรับงานเฉพาะ ไปจนถึงการซื้อเครื่องมือทางกายภาพและมิติ เราให้บริการเช่าซื้อตลอดจนการขายอุปกรณ์ทดสอบที่ใช้แล้ว เรายังระบุตำแหน่งอุปกรณ์อิเล็กทรอนิกส์ที่หายาก และมีตัวเลือกที่ยืดหยุ่นเพื่อตอบสนองความต้องการอุปกรณ์ที่เปลี่ยนแปลงตลอดเวลา

เช่าหรือซื้ออุปกรณ์นี้
Electronic instruments stacked on top of one another

ความสามารถของเรา

Micro Precision สามารถให้บริการสอบเทียบเครื่องมือบนอุปกรณ์จากการใช้งานที่หลากหลายสำหรับอุตสาหกรรมและสายธุรกิจเฉพาะ หากคุณมีความต้องการสอบเทียบที่ไม่ได้ระบุไว้ในพื้นที่นี้ โปรดติดต่อเรา

ไฟฟ้า

บริการห้องปฏิบัติการสอบเทียบทางไฟฟ้าที่ได้รับการรับรองจาก Micro Precision พร้อมด้วยมัลติมิเตอร์ เครื่องสอบเทียบมัลติฟังก์ชั่น ออสซิลโลสโคป และความสามารถในการจ่ายไฟ

เรียนรู้เพิ่มเติม

ออปติคัล

บริการห้องปฏิบัติการสอบเทียบแสง แสง และใยแก้วนำแสงที่ได้รับการรับรองจาก Micro Precision

เรียนรู้เพิ่มเติม

เคมี

เทอร์โมไดนามิกที่ได้รับการรับรอง Micro Precision & บริการห้องปฏิบัติการสอบเทียบเคมีที่มีความสามารถด้านอุณหภูมิ ความชื้น ชีววิทยาศาสตร์ และเภสัช

เรียนรู้เพิ่มเติม

RF - ไมโครเวฟ

บริการห้องปฏิบัติการสอบเทียบคลื่นความถี่วิทยุและไมโครเวฟที่ได้รับการรับรองจาก Micro Precision

เรียนรู้เพิ่มเติม

เครื่องกลและมิติ

บริการห้องปฏิบัติการสอบเทียบทางกลและมิติที่ได้รับการรับรองโดย Micro Precision พร้อมความสามารถในการรับแรงกด แรงบิด แรง การไหล ความเร็ว และความสามารถในการรับน้ำหนักของแม่แรงอากาศยาน

เรียนรู้เพิ่มเติม

เซมิคอนดักเตอร์

ANAB ได้รับการรับรองมาตรฐาน ISO/IEC 17025-2017 ความหนาของเวเฟอร์เซมิคอนดักเตอร์ที่ผ่านการรับรองและการสอบเทียบขั้นตอนที่มีความแม่นยำสูง

เรียนรู้เพิ่มเติม

ความต้องการสอบเทียบ ง่าย

อุปกรณ์ทดสอบแบบครบวงจรและบริการสอบเทียบเครื่องมือ

calibration-services

การสอบเทียบ

Micro Precision นำเสนอบริการและโซลูชันการสอบเทียบเครื่องมือและอุปกรณ์ในสถานที่และทั่วโลกที่ให้บริการในภาคอุตสาหกรรมและการใช้งานที่หลากหลาย

เรียนรู้เพิ่มเติม

Instrument Repair Services

ซ่อมแซม

บริการซ่อมเครื่องมือที่คุ้มค่าและคุ้มค่า

เรียนรู้เพิ่มเติม

Global Calibration Solutions

โซลูชั่นระดับโลก

ให้บริการเสริมด้านเทคนิคและคุณภาพ การสนับสนุน OEM และโซลูชั่นการจัดการสินทรัพย์

เรียนรู้เพิ่มเติม

Equipment Sales & Rental

ขายอุปกรณ์

ผ่านทางบริษัทในเครือ Micro Precision Test Equipment Inc. เรานำเสนอบริการเช่าและลีสซิ่งแก่ลูกค้า ซึ่งช่วยให้ลูกค้าของเรามีทางเลือกที่ยืดหยุ่นเพื่อตอบสนองความต้องการอุปกรณ์ที่เปลี่ยนแปลงตลอดเวลา

เรียนรู้เพิ่มเติม