Metrel MD 9060 Digital Multimeter
The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement, conductance measurement and fast one-handed operation. MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice.
Please use the request form to start a calibration services quote. You may also request equipment sales or repair services.
Service & Purchase | 价格 |
---|---|
Equipment repai … | Inquire for pricing |
Calibration wit … | Inquire for pricing |
Standard calibr … | Inquire for pricing |
Calibration inc … | Inquire for pricing |
Purchase equipm … | Inquire for pricing |
描述
MD 9060 TRMS, 500.000 counts LCD, 100k Hz Voltage Bandwidth Heavy Duty Industrial Multimeter
The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement, conductance measurement and fast one-handed operation. MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice. .
Standards applied
Instrument safety towards user
- IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
- IEC/EN 61000 Electromagnetic compatibility (EMC) series
- IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
- IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
- IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
- IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
- IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
- IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
- IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
- IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
- IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
- The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
- Directive EMC 2004/108/EC on electromagnetic compatibility
- IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
- IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
- IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
- IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
- IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety
- IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
- IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements
Properties
Measuring functions
- TRMS AC, DC voltage measurement;
- TRMS AC, DC current measurement;
- Capacitance measurement;
- Resistance measurement;
- Diode test;
- Mains supply frequency measurement;
- Frequency of digital signals measurement;
- Continuity test (acoustic signalling);
- Conductance measurement;
- Temperature measurement.
Key features
- TRMS: accurate readings on sinusoidal and non-sinusoidal signals.
- VFD: feature makes the instrument capable of measuring the true values in accordance with frequency.
- Auto-ranging: user can switch between auto and manual ranging.
- Temperature measurement: measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
- Lead alert: incorrect lead connection alert.
- Relative zero mode: relative function for comparing the difference between signals or removing background noise.
- MAX/MIN/AVG: recording of maximum, minimum and average values.
- Data Hold: data hold feature freezes the display for later view.
- Peak Hold: Crest (instantaneous peak) capture mode.
- PC Link: test results can be downloaded to the computer via the optional PC software.
- Safety: CAT IV / 1000 V overvoltage protection.
- Backlight: large bright 4 digits 500.000 counts dual LCD display with backlight for working in dark conditions.
Technical data
- Dimensions (w x h x l): 103 x 64,5 x 208 mm
- Mass (without accessories): 635 g
Applications
Preventative maintenance
- Voltage measurements
- Current measurements
- Frequency measurements
Troubleshooting
- Field service
- Electronics
- HVAC
General purpose
- Industrial testing
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
搜索产品
实验室校准
Micro Precision 在全球运营 36 个实验室,提供可靠的本地化支持
- 认证计量学家在北美、中美洲、南美洲、欧洲、亚洲和中东的实验室配备人员
- 全面的认证范围可满足广泛的客户需求
- 提供快速校准服务
- 提供接送服务
- 环境受控设施可确保高质量和准确的校准和测量。
实验室校准
Micro Precision 在全球运营 36 个实验室,提供可靠的本地化支持
- 认证计量学家在北美、中美洲、南美洲、欧洲、亚洲和中东的实验室配备人员
- 全面的认证范围可满足广泛的客户需求
- 提供快速校准服务
- 提供接送服务
- 环境受控设施可确保高质量和准确的校准和测量。
质量认证的测试设备维修服务
当一件设备发生故障时,您可以选择修理或更换该物品。通常,维修是一种经济有效的解决方案。 Micro Precision 的维修服务为我们的客户提供以下优势:
- 性价比高;通常低于 OEM
- 高效;周转时间通常比 OEM 好得多
- 灵活性;愿意与客户合作以满足他们的需求
- 保修维修
- 能够维修许多过时的仪器
质量认证的测试设备维修服务
当一件设备发生故障时,您可以选择修理或更换该物品。通常,维修是一种经济有效的解决方案。 Micro Precision 的维修服务为我们的客户提供以下优势:
- 性价比高;通常低于 OEM
- 高效;周转时间通常比 OEM 好得多
- 灵活性;愿意与客户合作以满足他们的需求
- 保修维修
- 能够维修许多过时的仪器
具有成本效益的测试设备选项
从为特定任务租赁专业电子设备到购买物理和尺寸工具,我们提供租赁服务以及二手测试设备销售。我们还定位难以找到的电子产品,并提供灵活的选择以满足不断变化的设备需求。
具有成本效益的测试设备选项
从为特定任务租赁专业电子设备到购买物理和尺寸工具,我们提供租赁服务以及二手测试设备销售。我们还定位难以找到的电子产品,并提供灵活的选择以满足不断变化的设备需求。