Inquire for pricing

The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement,  conductance measurement and fast one-handed operation.  MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice.

Please use the request form to start a calibration services quote. You may also request equipment sales or repair services.

Service & Purchase价格
Equipment repai …Inquire for pricing
Calibration wit …Inquire for pricing
Standard calibr …Inquire for pricing
Calibration inc …Inquire for pricing
Purchase equipm …Inquire for pricing

库存单位 MetrelMD 9060 分类 Manufacturer Model Number

描述

MD 9060 TRMS, 500.000 counts LCD, 100k Hz Voltage Bandwidth Heavy Duty Industrial Multimeter

The MD 9060 ranks among the most accurate multimeters with a large bandwidth and very high resolution. Metrel MD 9060 is equipped with a built-in VFD feature that makes the instrument capable of measuring the true values in accordance with frequency, large 2-line 500.000 counts LCD display, fast data acquisition and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement,  conductance measurement and fast one-handed operation.  MD 9060 has a wide range of extra features, including data hold, memory, min / max, average, differential, peak, peak / peak with extra fast 1ms response time, auto power off, frequency filter, reset and relative function. The MD 9060 is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance practice. .

Standards applied

Instrument safety towards user

  • IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
  • IEC/EN 61000 Electromagnetic compatibility (EMC) series
  • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
  • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
  • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
  • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
  • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
  • IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
  • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
  • IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
  • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
  • Directive EMC 2004/108/EC on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
  • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
  • IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
  • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements

Properties

Measuring functions

  • TRMS AC, DC voltage measurement;
  • TRMS AC, DC current measurement;
  • Capacitance measurement;
  • Resistance measurement;
  • Diode test;
  • Mains supply frequency measurement;
  • Frequency of digital signals measurement;
  • Continuity test (acoustic signalling);
  • Conductance measurement;
  • Temperature measurement.

Key features

  • TRMS: accurate readings on sinusoidal and non-sinusoidal signals.
  • VFD: feature makes the instrument capable of measuring the true values in accordance with frequency.
  • Auto-ranging: user can switch between auto and manual ranging.
  • Temperature measurement: measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
  • Lead alert: incorrect lead connection alert.
  • Relative zero mode: relative function for comparing the difference between signals or removing background noise.
  • MAX/MIN/AVG: recording of maximum, minimum and average values.
  • Data Hold: data hold feature freezes the display for later view.
  • Peak Hold: Crest (instantaneous peak) capture mode.
  • PC Link: test results can be downloaded to the computer via the optional PC software.
  • Safety: CAT IV / 1000 V overvoltage protection.
  • Backlight: large bright 4 digits 500.000 counts dual LCD display with backlight for working in dark conditions.

Technical data

  • Dimensions (w x h x l): 103 x 64,5 x 208 mm
  • Mass (without accessories): 635 g

Applications

Preventative maintenance

  • Voltage measurements
  • Current measurements
  • Frequency measurements

Troubleshooting

  • Field service
  • Electronics
  • HVAC

General purpose

  • Industrial testing
Main Features
Voltage DC
DC 1000 V
Voltage AC
Frequency
Voltage TRMS
AC 1000 V
Current DC
DC 10 A
Current AC
Current TRMS
AC 10 A
Other DMM measurements
Acoustic continuity
Resistance
Capacitance
Conductance
Diode test
Temperature measurement
Logic frequency
Automotive DMM measurements
% – Duty Cycle Function
Additional Features
Hand-Held
Hand-Held
Measurement detection
Incorrect lead connection alert
Low Pass filter
Variable frequency drive
100 kHz bandwidth
Data hold
Data hold
MAX hold
MAX/MIN/AVG recording
Self-Calibration
Relative zero
Display
LCD
Dual digital
Back Light
Power Supply
Battery Powered
Buzzer
Buzzer
Graphical user interface
Bar Graph
High precision resolution
High precision resolution
Optical Communication Port
Optical Communication Port
Special Accessories
Type K thermocouple probe for DMM
Type K thermocouple probe for DMM
PC Software Package
PC Software Package
PC Interface Set
Other applications
Preventative maintenance
Voltage measurements
Current measurements
Frequency measurements
Troubleshooting
Field service
Electronics
HVAC
General purpose
Industrial testing
Standards Applied
Instrument safety towards user
IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
IEC/EN 61000 Electromagnetic compatibility (EMC) series
IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
Directive EMC 2004/108/EC on electromagnetic compatibility
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety
IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements
Product ManualDownload

搜索产品


实验室校准

Micro Precision 在全球运营 36 个实验室,提供可靠的本地化支持

  • 认证计量学家在北美、中美洲、南美洲、欧洲、亚洲和中东的实验室配备人员
  • 全面的认证范围可满足广泛的客户需求
  • 提供快速校准服务
  • 提供接送服务
  • 环境受控设施可确保高质量和准确的校准和测量。
Calibration equipment and workspace
本设备的校准服务

实验室校准

Micro Precision 在全球运营 36 个实验室,提供可靠的本地化支持

  • 认证计量学家在北美、中美洲、南美洲、欧洲、亚洲和中东的实验室配备人员
  • 全面的认证范围可满足广泛的客户需求
  • 提供快速校准服务
  • 提供接送服务
  • 环境受控设施可确保高质量和准确的校准和测量。
本设备的校准服务
Calibration equipment and workspace

质量认证的测试设备维修服务

当一件设备发生故障时,您可以选择修理或更换该物品。通常,维修是一种经济有效的解决方案。 Micro Precision 的维修服务为我们的客户提供以下优势:

  • 性价比高;通常低于 OEM
  • 高效;周转时间通常比 OEM 好得多
  • 灵活性;愿意与客户合作以满足他们的需求
  • 保修维修
  • 能够维修许多过时的仪器
Motherboard being repaired with soldering iron
本设备维修服务
Motherboard being repaired with soldering iron

质量认证的测试设备维修服务

当一件设备发生故障时,您可以选择修理或更换该物品。通常,维修是一种经济有效的解决方案。 Micro Precision 的维修服务为我们的客户提供以下优势:

  • 性价比高;通常低于 OEM
  • 高效;周转时间通常比 OEM 好得多
  • 灵活性;愿意与客户合作以满足他们的需求
  • 保修维修
  • 能够维修许多过时的仪器
本设备维修服务

具有成本效益的测试设备选项

从为特定任务租赁专业电子设备到购买物理和尺寸工具,我们提供租赁服务以及二手测试设备销售。我们还定位难以找到的电子产品,并提供灵活的选择以满足不断变化的设备需求。

Electronic instruments stacked on top of one another
租用或购买此设备

具有成本效益的测试设备选项

从为特定任务租赁专业电子设备到购买物理和尺寸工具,我们提供租赁服务以及二手测试设备销售。我们还定位难以找到的电子产品,并提供灵活的选择以满足不断变化的设备需求。

租用或购买此设备
Electronic instruments stacked on top of one another

我们的能力

Micro Precision 可以为特定行业和业务线的各种应用中的设备执行仪器校准服务。如果您有此区域未列出的校准需求,请联系我们

电气

Micro Precision 认可的电气校准实验室服务,具有万用表、多功能校准器、示波器和电源功能。

学到更多

光学的

Micro Precision 认可的光学、光和光纤校准实验室服务。

学到更多

化工

Micro Precision 认可的热力学和具有温度、湿度、生命科学和制药能力的化学校准实验室服务。

学到更多

射频 - 微波

Micro Precision 认可的射频和微波校准实验室服务。

学到更多

机械和尺寸

Micro Precision 认可的机械和尺寸校准实验室服务,具有压力、扭矩、力、流量、速度和飞机千斤顶负载能力。

学到更多

半导体

ANAB 获得 ISO/IEC 17025-2017 认证 半导体晶圆厚度和精密步高校准。

学到更多

校准需求。简化。

全栈测试设备和仪器校准服务。

calibration-services

校准

Micro Precision 提供现场和全球仪器和设备校准服务和解决方案,服务于广泛的行业部门和应用。

学到更多

Instrument Repair Services

修理

具有成本效益和高效的仪器维修服务。

学到更多

Global Calibration Solutions

全球解决方案

提供技术和质量增值服务、OEM 支持和资产管理解决方案。

学到更多

Equipment Sales & Rental

设备销售

通过我们的姊妹公司 Micro Precision Test Equipment Inc.,我们为客户提供租赁服务,为客户提供灵活的选择,以满足不断变化的设备需求。

学到更多