Your Trusted Load Cell Calibration Provider
Micro Precision is an ISO/IEC 17025:2017 accredited calibration provider operating a global network of more than 50 labs. Our load cell calibration services deliver NIST-traceable measurement results backed by documented accreditation, serving aerospace, defense, medical device, and manufacturing quality programs with in-lab and on-site service options.
Our load cell calibration services are performed under ISO/IEC 17025:2017 accreditation with NIST-traceable measurement references. Every calibration produces a certificate of calibration documenting as-found and as-left conditions, providing the audit-ready documentation required for ISO 9001, AS9100, FDA 21 CFR Part 820, and other quality management systems.
Our accredited labs calibrate a wide variety of load cell types and capacities, from bench-scale force sensors to high-capacity structural test cells. Industries served include aerospace and defense, medical device manufacturing, automotive production, industrial manufacturing, pharmaceutical, and research and testing laboratories. Our mechanical and dimensional calibration capabilities extend across the full force measurement spectrum, supporting quality programs from incoming inspection through final acceptance testing.
Why Load Cell Calibration Matters
Uncalibrated load cells introduce systematic measurement error into force data, compromising product quality, structural safety, and regulatory documentation. ANSI/NCSL Z540.3 and ISO 10012 require that force measurement instruments used in quality-critical processes be calibrated at defined intervals against traceable standards. Calibration is not optional for operations subject to AS9100, ISO 9001, or FDA quality system requirements.
For quality managers and QA directors, uncalibrated force measurement equipment creates audit findings and compliance gaps that can delay certification or trigger corrective action requests. For lab technicians and metrologists, sensor drift over time invalidates force and weight data unless calibration history is documented and traceable to national measurement standards.
For procurement and compliance teams, selecting an accredited load cell calibration provider ensures that certificates of calibration meet the documentation requirements of third-party auditors, government regulators, and prime contractors across defense, aerospace, and medical device supply chains.
Ensure Accurate Load Cell Calibration
Accurate load cell calibration requires a documented, repeatable process tied to traceable measurement standards. Micro Precision receives each instrument, inspects it for physical condition, applies known force references across the calibration range, adjusts output where necessary, and issues a certificate of calibration documenting as-found and as-left measurement data.
Our calibration process follows these steps for every instrument:
- Receive and inspect: the instrument is logged, inspected for physical damage, and prepared for testing
- As-found measurement: the load cell is tested at defined force intervals using NIST-traceable reference standards, and pre-adjustment readings are recorded
- Adjustment: where readings fall outside acceptable tolerance, the instrument is adjusted to bring output into specification
- As-left measurement: post-adjustment readings are recorded to document final calibrated performance
- Documentation: a certificate of calibration is issued with full measurement data, reference standard traceability, and calibration date
- Return: the calibrated instrument is returned with its certificate of calibration
Standard and rush turnaround options are available. Contact our team when requesting a quote to discuss lead times for your specific load cell type and service level.
Our Calibration Options
Micro Precision offers two load cell calibration delivery modes: in-lab calibration at one of our accredited facilities, and on-site calibration performed at your location by accredited technicians. Both options produce a NIST-traceable certificate of calibration. Rush service is available for time-sensitive calibration requirements.
In-Lab Calibration
Ship your load cells to the nearest Micro Precision accredited calibration facility for service under controlled laboratory conditions. In-lab calibration is suited for portable sensors, bench-scale force transducers, and instruments that can be safely transported without risk of damage or misalignment. Our lab network spans more than 50 locations, keeping transit times and turnaround short.
On-Site Calibration
Micro Precision technicians travel to your facility to calibrate load cells in place. On-site service is the preferred option for permanently installed force measurement systems, high-capacity structural test cells, and platform or floor scale assemblies where removing the sensor creates downtime or re-zeroing risk. Learn more about our on-site calibration services and how to schedule a visit.
Rush Calibration
Rush turnaround is available for production-critical instruments. Request a rush option when submitting your calibration quote to confirm current availability and lead time.
Load Cell Types We Calibrate
Micro Precision calibrates a variety of load cell types and force measurement instruments across a wide range of capacities. Our accredited instrument calibration services cover the following load cell types:
- Compression load cells
- Tension load cells
- S-type (S-beam) load cells
- Shear beam load cells
- Double-ended shear beam load cells
- Button and pancake load cells
- Load pins and clevis pins
- Crane scale load cells
- Platform and floor scale load cells
- Force transducers and force sensors
We service instruments from a variety of manufacturers, including Interface, FUTEK, Honeywell, HBK (Hottinger Baldwin Messtechnik), Omega, Mettler Toledo, Rice Lake, Vishay, and Flintec. If your instrument model or manufacturer is not listed, contact us to confirm service availability for your specific equipment.
Service Levels Offered
Micro Precision offers three load cell calibration service levels to match your compliance requirements and documentation needs. Select the tier that aligns with your quality management system obligations and audit requirements.
| Type of Service | Traceable | Traceable with Data | Accredited (ISO:IEC 17025:2017, Z540.3) |
|---|---|---|---|
| Calibrated to manufacturers specifications traceable to SI Units | |||
| ISO 9000 Compliant | |||
| Calibration certificates, data, maintained on secure web based tool (CDM) | |||
| Detailed calibration certificates and calibration stickers | |||
| Instrument adjustment (if found out of tolerance) | |||
| ANSI/NCSL Z540-1 compliant | |||
| Calibration Data | |||
| Logo from Accreditation body, Expanded Measurement Uncertainty | |||
| ANSI/NCSL Z540.3 compliant |
Please complete our quick Load Cell calibration & repair service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)
Load Cell Services
If you have any inquiries, or simply wish to connect with us, we'd love to hear from you! Please don't hesitate to reach out to us.
"*" indicates required fields
FAQs
A calibration certificate from an ISO/IEC 17025:2017 accredited laboratory documents the instrument identification, calibration date, measurement standards used, environmental conditions during calibration, as-found performance data, as-left performance data after any adjustments, and the laboratory’s accreditation details. This documentation satisfies traceability requirements for ISO 9001, AS9100, and FDA quality management systems.
NIST traceable calibration means the measurement standards used in your load cell calibration are linked to the SI unit system through an unbroken chain of calibrations ultimately referenced to the National Institute of Standards and Technology. This traceability is a core requirement of ISO/IEC 17025:2017 accreditation and is documented on every certificate of calibration issued by Micro Precision.
Yes. Micro Precision provides on-site load cell calibration services for permanently installed sensors, high-capacity load frames, and systems where removing the instrument from service is impractical. On-site calibration is performed by accredited technicians using NIST-traceable portable reference standards, and the service produces a fully documented certificate of calibration.
A load cell requires recalibration when it reaches its scheduled calibration due date, after any overload or physical impact event, when measurement readings are inconsistent or drift outside expected ranges, or when a quality audit or regulatory inspection requires current calibration documentation. Establishing a defined calibration interval tied to your quality management system is the most reliable approach.
ISO/IEC 17025:2017 requires that all measurement equipment used in calibration and testing processes be calibrated with documented traceability to SI units. Any load cell used in a quality-critical process must carry a current calibration certificate. ISO 9001 and AS9100 set comparable documentation requirements for measuring equipment used in manufacturing and testing operations.
Calibration determines the relationship between a load cell’s output and the applied force, adjusts the instrument when needed, and produces a certificate documenting full measurement data. Verification confirms whether the instrument meets a specific tolerance requirement without characterizing its performance curve or adjusting it. ISO/IEC 17025:2017 accredited calibration provides a higher level of documented traceability than verification alone.